Match the vent pipe to the furnace maker s recommendations either sheet metal or vinyl.
How far should vent pipe stick out of roof.
Extension of vent pipes through a roof shall be terminated not less than 12 inches above it.
It is a vertical pipe attached to a drain line and runs through the roof of your home.
The best way to be sure your pipe vents are clear and pipe boots are functional is to have them inspected regularly by either an experienced roofer or by looking yourself.
Above the roof plumbing vent height.
12 4 4 location of vent terminal.
I d maybe try to tie that existing 2 vent into your new 3.
Obviously look to take out the palm trees to the west as well.
The vent stack is the pipe leading to the main roof vent.
Extend the vent pipe at least.
Vent pipes shall terminate not less than 6 inches above the roof measured from the highest point where the vent intersects the roof.
Set the collar with the wide flange at the bottom on the surface of the roof.
Where a roof is used for any purpose other than weather protection vents shall extend at least 7 feet above the roof and shall be properly supported.
In other words the highest point within a 10 foot circle of the pipe.
Does anyone know what legal height requirements there are for vent pipes or as long as it sticks out of the roof its all sweet.
Upc i 906 1 and 906 2.
If the pipe is farther than 10 feet from the roof peak it must be 2 feet above the highest point of the roof within 10 feet.
At 757 506 5019 or email us here if you notice your pipe boots are damaged have a roof leak or just want your roof inspected.
Call pro systems inc.
I am looking at shortening the height of my vent pipe on the roof to allow for solar panel expansion in the future.